Deltec®

PORT-A-CATH®, PORT-A-CATH®II and P.A.S. PORT® POWER P.A.C. Implantable Access Systems

The proven performance of PORT-A-CATH® systems now gives you POWER

The PORT-A-CATH® and P.A.S. PORT® POWER P.A.C. systems provide an additional option of power injecting contrast media for certain types of diagnostic imaging scans.
  • Easy to implant
  • Lightweight
  • Easy to maintain
  • Intended to reduce complication rates1
  • Easy to explant

The Power of Choice

The PORT-A-CATH® and P.A.S. PORT® POWER P.A.C. systems are available in more configurations than any other manufacturer to give you the best choice for your patients:
  • Titanium single-lumen standard
  • Titanium single-lumen low profile
  • Polysulfone single-lumen standard in two catheter sizes
  • Polysulfone single-lumen low profile in two catheter sizes
  • Polysulfone dual-lumen low profile in two catheter sizes
  • Peripheral titanium single-lumen for arm placement
1. Biffi, Robert M.D. Use of totally implantable central venous access ports for high-dose chemotherapy and peripheral blood stem cell transplantation: results of a monocentre series of 376 patients. Annals of Oncology 2004; 15:296-300.

Ordering Information
Box quantity: 1


Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.

Product Benefits
  • MR Conditional up to 3-Tesla
  • Radiopaque CT marking embedded into port septum for visibility under x-ray
  • Allows for power injections up to 5mL/sec and 300psi pressure rating
  • Compatible with all power needles
  • Radiopaque CT marking embedded into port septum for visibility under x-ray

PORT-A-CATH®, PORT-A-CATH®II and P.A.S. PORT® POWER P.A.C. Implantable Access Systems

The proven performance of PORT-A-CATH® systems now gives you POWER

The PORT-A-CATH® and P.A.S. PORT® POWER P.A.C. systems provide an additional option of power injecting contrast media for certain types of diagnostic imaging scans.
  • Easy to implant
  • Lightweight
  • Easy to maintain
  • Intended to reduce complication rates1
  • Easy to explant

The Power of Choice

The PORT-A-CATH® and P.A.S. PORT® POWER P.A.C. systems are available in more configurations than any other manufacturer to give you the best choice for your patients:
  • Titanium single-lumen standard
  • Titanium single-lumen low profile
  • Polysulfone single-lumen standard in two catheter sizes
  • Polysulfone single-lumen low profile in two catheter sizes
  • Polysulfone dual-lumen low profile in two catheter sizes
  • Peripheral titanium single-lumen for arm placement
1. Biffi, Robert M.D. Use of totally implantable central venous access ports for high-dose chemotherapy and peripheral blood stem cell transplantation: results of a monocentre series of 376 patients. Annals of Oncology 2004; 15:296-300.

Ordering Information
Box quantity: 1


Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.

Product Benefits
  • MR Conditional up to 3-Tesla
  • Radiopaque CT marking embedded into port septum for visibility under x-ray
  • Allows for power injections up to 5mL/sec and 300psi pressure rating
  • Compatible with all power needles
  • Radiopaque CT marking embedded into port septum for visibility under x-ray
Read More  

    Polysulfone/Titanium Portals with PolyFlow® Polyurethane Catheters

    MR Conditional up to 3-Tesla, power injection up to 5 mL/sec and 300 psi

    Reorder Code Type Description Introducer Needle Catheter Material OD (mm) ID (mm) Length (cm)
    21-4452-24 Kit Single-lumen Portal 6 Fr Polyurethane 1.9 1.0 76
    21-4453-24 Tray Single-lumen Portal 6 Fr Polyurethane 1.9 1.0 76
    21-4463-24
    Tray
    Single-lumen Portal Preassembled
    6 Fr
    Polyurethane
    1.9
    1.0 76
    21-4454-24 Kit Single-lumen Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4455-24 Tray Single-lumen Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4465-24 Tray Single-lumen Portal Preassembled 8.5 Fr Polyurethane 2.6 1.6 76
    21-4482-24
    Kit Single-lumen Low Profile™ Portal
    6 Fr
    Polyurethane
    1.9
    1.0 76
    21-4483-24
    Tray Single-lumen Low Profile™ Portal
    6 Fr
    Polyurethane
    1.9
    1.0 76
    21-4485-24
    Tray Single-lumen Low Profile™ Portal 
    6 Fr Polyurethane
    1.9 1.0 76
    21-4470-24 Kit Single-lumen Low Profile™ Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4471-24 Tray Single-lumen Low Profile™ Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4473-24 Tray Single-lumen Low Profile™ Portal Preassembled 8.5 Fr Polyurethane 2.6 1.6 76
    21-8468-24 Tray Dual-lumen Low Profile™ Portal
    10 Fr Polyurethane 3.2 1.4/1.4 76
    21-8466-24 Tray Dual-lumen Low Profile™ Portal
    7 Fr Polyurethane 2.2 1.0/1.0 76
    Kits include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle, vein pick, and Point-Lok® device.
    Trays include:Portal, catheter, PORT-A-CATH® straight needle, blunt needle (except preassembled systems), vein pick, 18G extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH® needle, GRIPPER PLUS® POWER P.A.C. safety needle, 2 syringes, tunneling tool and Point-Lok® device(s).
    All systems are unassembled, unless otherwise noted.

    PORT-A-CATH® POWER P.A.C. Systems with SafeSheath® Valved Peel-Away Introducers

    Introducer sheath length – 13 cm Dilator sheath length – 18 cm

    Reorder Code Type Description Introducer Needle Catheter Material OD (mm) Length (cm) Connector
    21-4474-24 Tray Single-lumen Portal 8.5 Fr Polyurethane 2.9 76 ULTRA-LOCK®
    connector
    21-4475-24 Tray Single-lumen Low Profile Portal 8.5 Fr Polyurethane 2.6 76 ULTRA-LOCK®
    connector
    21-4476-24 Tray Single-lumen Portal 6 Fr Polyurethane 1.9 76 ULTRA-LOCK®
    connector
    21-4477-24 Tray Single-lumen Low Profile Portal 6 Fr Polyurethane 1.9 76 ULTRA-LOCK®
    connector
    21-8469-24 Tray Dual-lumen Low Profile Portal 7 Fr Polyurethane 2.2 76 WING-LOCK®
    connector
    21-8470-24 Tray Dual-lumen Low Profile Portal 10 Fr Polyurethane 3.2 76 WING-LOCK®
    connector
    SafeSheath® introducers are available in Smiths Medical PORT-A-CATH® system trays and also as separate sets.

    PORT-A-CATH® POWER P.A.C. Titanium Contoured Portals with PolyFlow® Polyurethane Catheters

    MR Conditional up to 3-Tesla, power injection up to 5 mL/sec and 300 psi

    Reorder Code Type Description Introducer Needle Catheter Material OD (mm) ID (mm) Length (cm)
    21-4422-24 Kit Single-lumen Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4423-24 Tray Single-lumen Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4424-24 Kit Single-lumen Portal 6 Fr Polyurethane 1.9 1.0 76
    21-4425-24 Tray Single-lumen Portal 6 Fr Polyurethane 1.9 1.0 76
    21-4436-24 Kit Single-lumen Low Profile™ Portal 6 Fr Polyurethane 1.9 1.0 76
    21-4437-24 Tray Single-lumen Low Profile™ Portal 6 Fr Polyurethane 1.9 1.0 76
    Kits include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle, vein pick, and Point-Lok® device.
    Trays include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle (except preassembled systems), vein pick, 18G extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH® needle, GRIPPER PLUS® POWER P.A.C. safety needle(s), 2 syringes, tunneling tool and Point-Lok® device(s).
    All systems are unassembled, unless otherwise noted.

    P.A.S. PORT® T2 POWER P.A.C. Titanium Implantable Peripheral Venous Access Systems

    Titanium Contoured Portals with PolyFlow® Polyurethane Catheters

    MR Conditional up to 3-Tesla, power injection up to 5 mL/sec and 300 psi

    Reorder Code Type Introducer Needle Catheter Material OD (mm) ID (mm) Length (cm)
    21-4872-24 Kit 6 Fr Polyurethane 1.9 1.0 76
    21-4873-24 Tray 6 Fr Polyurethane 1.9 1.0 76
    Kits include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle, vein pick, and Point-Lok® device.
    Trays include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle (except preassembled systems), vein pick, 18G extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH® needle, GRIPPER PLUS® POWER P.A.C. safety needle(s), 2 syringes, tunneling tool and Point-Lok® device(s).
    All systems are unassembled, unless otherwise noted.

    PORT-A-CATH® II Systems with SafeSheath® Valved Peel-Away Introducers

    Introducer sheath length – 13 cm Dilator sheath length – 18 cm

    Reorder Code Type Description Introducer Needle Catheter Material OD (mm) Length (cm) Connector
    21-4066-24 Tray Single-lumen
    Portal
    8.5 Fr Polyurethane 2.6 76 ULTRA-LOCK®
    connector
    21-4067-24 Tray Single-lumen
    Portal
    6 Fr Polyurethane 1.9 76 ULTRA-LOCK®
    connector
    21-4068-24
    Tray Single-lumen
    Low Profile
    Portal
    8.5 Fr Polyurethane
    2.6 76 ULTRA-LOCK®
    connector
    21-4069-24
    Tray Single-lumen
    Low Profile
    Portal
    6 Fr Polyurethane
    1.9
    76 ULTRA-LOCK®
    connector
    SafeSheath® introducers are available in Smiths Medical PORT-A-CATH® system trays and also as separate sets.

    PORT-A-CATH® II Polysulfone/Titanium Portals with PolyFlow® Polyurethane Catheters

    MR Conditional up to 3-Tesla

    Reorder Code Type Description Introducer Needle Catheter Material OD (mm) ID (mm) Length (cm)
    21-4052-24 Kit Single-lumen Portal 6 Fr Polyurethane 1.9 1.0 76
    21-4053-24 Tray Single-lumen Portal 6 Fr Polyurethane 1.9 1.0 76
    21-4054-24 Kit Single-lumen Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4055-24 Tray Single-lumen Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4063-24
    Tray
    Single-lumen Portal Preassembled

    6 Fr  Polyurethane
    1.9 1.0 76
    21-4065-24 Tray Single-lumen Portal Preassembled 8.5 Fr Polyurethane 2.6 1.6 76
    21-4082-24
    Kit Single-lumen Low Profile Portal
    6 Fr
    Polyurethane
    1.9
    1.0 76
    21-4083-24
    Tray Single-lumen Low Profile Portal
    6 Fr
    Polyurethane
    1.9
    1.0 76
    21-4084-24
    Kit Single-lumen Low Profile Portal Preassembled
    6 Fr Polyurethane
    1.9 1.0 76
    21-4085-24
    Tray Single-lumen Low Profile Portal 
    6 Fr Polyurethane
    1.9 1.0 76
    21-4070-24 Kit Single-lumen Low Profile Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4071-24 Tray Single-lumen Low Profile Portal 8.5 Fr Polyurethane 2.6 1.6 76
    21-4073-24 Tray Single-lumen Low Profile™ Portal Preassembled
    8.5 Fr Polyurethane 2.6 1.6 76
    21-8466-24
    Tray Dual-lumen Low Profile Portal
    7 Fr Polyurethane
    2.2
    1.0/1.0
    76
    21-8468-24 Tray Dual-lumen Low Profile Portal
    10 Fr Polyurethane 3.2 1.4/1.4 76
    Kits include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle (except preassembled systems), vein pick and Point-Lok® device(s).
    Trays include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle (except preassembled systems), vein pick, 18G extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH® needle, GRIPPER PLUS® safety needle, 2 syringes, tunneling tool and Point-Lok® device.
    All systems are unassembled, unless otherwise noted.

    PORT-A-CATH® II Polysulfone/Titanium Portals with Silicone Catheters

    MR Conditional up to 3-Tesla

    Reorder Code Type Description Introducer Needle Catheter Material OD (mm) ID (mm) Length (cm)
    21-4050-24 Kit Single-lumen Portal 9 Fr Silicone
    2.8 1.0 76
    21-4051-24 Tray Single-lumen Portal 9 Fr Silicone
    2.8 1.0 76
    Kits include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle (except preassembled systems), vein pick and Point-Lok® device(s).
    Trays include: Portal, catheter, PORT-A-CATH® straight needle, blunt needle (except preassembled systems), vein pick, 18G extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH® needle, GRIPPER PLUS® safety needle, 2 syringes, tunneling tool and Point-Lok® device.
    All systems are unassembled, unless otherwise noted.

    Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.

    This page was last updated: