Polysulfone/Titanium Portals with PolyFlow® Polyurethane Catheters
MR Conditional up to 3-Tesla, power injection up to 5 mL/sec and 300 psi
Reorder Code |
Type |
Description |
Introducer Needle |
Catheter Material |
OD (mm) |
ID (mm) |
Length (cm) |
21-4452-24 |
Kit |
Single-lumen Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4453-24 |
Tray |
Single-lumen Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4463-24
|
Tray
|
Single-lumen Portal Preassembled
|
6 Fr
|
Polyurethane
|
1.9
|
1.0 |
76 |
21-4454-24 |
Kit |
Single-lumen Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4455-24 |
Tray |
Single-lumen Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4465-24 |
Tray |
Single-lumen Portal Preassembled |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4482-24
|
Kit |
Single-lumen Low Profile™ Portal
|
6 Fr
|
Polyurethane
|
1.9
|
1.0 |
76 |
21-4483-24
|
Tray |
Single-lumen Low Profile™ Portal
|
6 Fr
|
Polyurethane
|
1.9
|
1.0 |
76 |
21-4485-24
|
Tray |
Single-lumen Low Profile™ Portal
|
6 Fr |
Polyurethane
|
1.9 |
1.0 |
76 |
21-4470-24 |
Kit |
Single-lumen Low Profile™ Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4471-24 |
Tray |
Single-lumen Low Profile™ Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4473-24 |
Tray |
Single-lumen Low Profile™ Portal Preassembled |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-8468-24 |
Tray |
Dual-lumen Low Profile™ Portal
|
10 Fr |
Polyurethane |
3.2 |
1.4/1.4 |
76 |
21-8466-24 |
Tray |
Dual-lumen Low Profile™ Portal
|
7 Fr |
Polyurethane |
2.2 |
1.0/1.0 |
76 |
Kits include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle, vein pick, and Point-Lok
® device.
Trays include:Portal, catheter, PORT-A-CATH
® straight needle, blunt needle (except preassembled systems), vein pick, 18G extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH
® needle, GRIPPER PLUS
® POWER P.A.C. safety needle, 2 syringes, tunneling tool and Point-Lok
® device(s).
All systems are unassembled, unless otherwise noted.
PORT-A-CATH® POWER P.A.C. Systems with SafeSheath® Valved Peel-Away Introducers
Introducer sheath length – 13 cm Dilator sheath length – 18 cm
Reorder Code |
Type |
Description |
Introducer Needle |
Catheter Material |
OD (mm) |
Length (cm) |
Connector
|
21-4474-24 |
Tray |
Single-lumen Portal |
8.5 Fr |
Polyurethane |
2.9 |
76 |
ULTRA-LOCK®
connector
|
21-4475-24 |
Tray |
Single-lumen Low Profile™ Portal |
8.5 Fr |
Polyurethane |
2.6 |
76 |
ULTRA-LOCK®
connector
|
21-4476-24 |
Tray |
Single-lumen Portal |
6 Fr |
Polyurethane |
1.9 |
76 |
ULTRA-LOCK®
connector
|
21-4477-24 |
Tray |
Single-lumen Low Profile™ Portal |
6 Fr |
Polyurethane |
1.9 |
76 |
ULTRA-LOCK®
connector
|
21-8469-24 |
Tray |
Dual-lumen Low Profile™ Portal |
7 Fr |
Polyurethane |
2.2 |
76 |
WING-LOCK®
connector
|
21-8470-24 |
Tray |
Dual-lumen Low Profile™ Portal |
10 Fr |
Polyurethane |
3.2 |
76 |
WING-LOCK®
connector
|
SafeSheath
® introducers are available in Smiths Medical PORT-A-CATH
® system trays and also as separate sets.
PORT-A-CATH® POWER P.A.C. Titanium Contoured Portals with PolyFlow® Polyurethane Catheters
MR Conditional up to 3-Tesla, power injection up to 5 mL/sec and 300 psi
Reorder Code |
Type |
Description |
Introducer Needle |
Catheter Material |
OD (mm) |
ID (mm) |
Length (cm) |
21-4422-24 |
Kit |
Single-lumen Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4423-24 |
Tray |
Single-lumen Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4424-24 |
Kit |
Single-lumen Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4425-24 |
Tray |
Single-lumen Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4436-24 |
Kit |
Single-lumen Low Profile™ Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4437-24 |
Tray |
Single-lumen Low Profile™ Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
Kits include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle, vein pick, and Point-Lok
® device.
Trays include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle (except preassembled systems), vein pick, 18G
extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH
® needle,
GRIPPER PLUS
® POWER P.A.C. safety needle(s), 2 syringes, tunneling tool and Point-Lok
® device(s).
All systems are unassembled, unless otherwise noted.
P.A.S. PORT® T2 POWER P.A.C. Titanium Implantable Peripheral Venous Access Systems
Titanium Contoured Portals with PolyFlow® Polyurethane Catheters
MR Conditional up to 3-Tesla, power injection up to 5 mL/sec and 300 psi
Reorder Code |
Type |
Introducer Needle |
Catheter Material |
OD (mm) |
ID (mm) |
Length (cm) |
21-4872-24 |
Kit |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4873-24 |
Tray |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
Kits include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle, vein pick, and Point-Lok
® device.
Trays include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle (except preassembled systems), vein pick, 18G
extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH
® needle,
GRIPPER PLUS
® POWER P.A.C. safety needle(s), 2 syringes, tunneling tool and Point-Lok
® device(s).
All systems are unassembled, unless otherwise noted.
PORT-A-CATH® II Systems with SafeSheath® Valved Peel-Away Introducers
Introducer sheath length – 13 cm Dilator sheath length – 18 cm
Reorder Code |
Type |
Description |
Introducer Needle |
Catheter Material |
OD (mm) |
Length (cm) |
Connector
|
21-4066-24 |
Tray |
Single-lumen
Portal
|
8.5 Fr |
Polyurethane |
2.6 |
76 |
ULTRA-LOCK®
connector
|
21-4067-24 |
Tray |
Single-lumen
Portal
|
6 Fr |
Polyurethane |
1.9 |
76 |
ULTRA-LOCK®
connector
|
21-4068-24
|
Tray |
Single-lumen
Low Profile™
Portal
|
8.5 Fr |
Polyurethane
|
2.6 |
76 |
ULTRA-LOCK®
connector
|
21-4069-24
|
Tray |
Single-lumen
Low Profile™
Portal
|
6 Fr |
Polyurethane
|
1.9
|
76 |
ULTRA-LOCK®
connector
|
SafeSheath
® introducers are available in Smiths Medical PORT-A-CATH
® system trays and also as separate sets.
PORT-A-CATH® II Polysulfone/Titanium Portals with PolyFlow® Polyurethane Catheters
MR Conditional up to 3-Tesla
Reorder Code |
Type |
Description |
Introducer Needle |
Catheter Material |
OD (mm) |
ID (mm) |
Length (cm) |
21-4052-24 |
Kit |
Single-lumen Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4053-24 |
Tray |
Single-lumen Portal |
6 Fr |
Polyurethane |
1.9 |
1.0 |
76 |
21-4054-24 |
Kit |
Single-lumen Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4055-24 |
Tray |
Single-lumen Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4063-24
|
Tray
|
Single-lumen Portal Preassembled
|
6 Fr |
Polyurethane
|
1.9 |
1.0 |
76 |
21-4065-24 |
Tray |
Single-lumen Portal Preassembled |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4082-24
|
Kit |
Single-lumen Low Profile™ Portal
|
6 Fr
|
Polyurethane
|
1.9
|
1.0 |
76 |
21-4083-24
|
Tray |
Single-lumen Low Profile™ Portal
|
6 Fr
|
Polyurethane
|
1.9
|
1.0 |
76 |
21-4084-24
|
Kit |
Single-lumen Low Profile™ Portal Preassembled
|
6 Fr |
Polyurethane
|
1.9 |
1.0 |
76 |
21-4085-24
|
Tray |
Single-lumen Low Profile™ Portal
|
6 Fr |
Polyurethane
|
1.9 |
1.0 |
76 |
21-4070-24 |
Kit |
Single-lumen Low Profile™ Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4071-24 |
Tray |
Single-lumen Low Profile™ Portal |
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-4073-24 |
Tray |
Single-lumen Low Profile™ Portal Preassembled
|
8.5 Fr |
Polyurethane |
2.6 |
1.6 |
76 |
21-8466-24
|
Tray |
Dual-lumen Low Profile™ Portal
|
7 Fr |
Polyurethane
|
2.2
|
1.0/1.0
|
76 |
21-8468-24 |
Tray |
Dual-lumen Low Profile™ Portal
|
10 Fr |
Polyurethane |
3.2 |
1.4/1.4 |
76 |
Kits include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle (except preassembled systems), vein pick and
Point-Lok
® device(s).
Trays include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle (except preassembled systems), vein pick, 18G
extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH
® needle,
GRIPPER PLUS
® safety needle, 2 syringes, tunneling tool and Point-Lok
® device.
All systems are unassembled, unless otherwise noted.
PORT-A-CATH® II Polysulfone/Titanium Portals with Silicone Catheters
MR Conditional up to 3-Tesla
Reorder Code |
Type |
Description |
Introducer Needle |
Catheter Material |
OD (mm) |
ID (mm) |
Length (cm) |
21-4050-24 |
Kit |
Single-lumen Portal |
9 Fr |
Silicone
|
2.8 |
1.0 |
76 |
21-4051-24 |
Tray |
Single-lumen Portal |
9 Fr |
Silicone
|
2.8 |
1.0 |
76 |
Kits include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle (except preassembled systems), vein pick and
Point-Lok
® device(s).
Trays include: Portal, catheter, PORT-A-CATH
® straight needle, blunt needle (except preassembled systems), vein pick, 18G
extra thin wall introducer needle, “J” guidewire(s), vessel dilator/sheath introducer assembly, 90° PORT-A-CATH
® needle,
GRIPPER PLUS
® safety needle, 2 syringes, tunneling tool and Point-Lok
® device.
All systems are unassembled, unless otherwise noted.