CADD®-Solis Ambulatory Infusion Pump with Wireless Communications

A SMART SYSTEM THAT COMBINES SMART CONNECTIVITY WITH SAFE AMBULATORY INFUSION

Wireless communication transforms the CADD®-Solis system from a standalone pump to an integrated system with PharmGuard® Server software that helps increase efficiency and safety within hospitals, decrease cost, and improve outcomes.

  • Provide actionable reports when you need them, where you want them
  • Deploy protocol libraries and software updates from the server to the pump
  • Helps improve safety and effectiveness of drug protocols with PharmGuard® Device Reports
  • Monitor drug dosing
  • Enable patient mobility to assist in faster recoveries and reduced length of stay and complications

Note: The wireless feature can be turned off or on without affecting pump delivery. Wireless connection does not impact pump delivery or data retention.

Product Benefits

CADD®-Solis is a small and lightweight pump that promotes clinician convenience.  

Programmed Intermittent Bolus – PIB delivery improves patient satisfaction, decreases drug use and reduces unplanned clinician interventions by reducing failed blocks and motor block.

Innovative therapies and task based menus - Therapy based protocol  library reduce the risk of adverse drug events and promote best practices. CADD®-Solis programming supports PCA, PCEA, PIB, and PNB therapies. The intuitive task based software and therapy-based drug protocol library is familiar to users, promoting usability and safety.  

Scalable platform - Designed to satisfy hospital’s current and future clinical requirements and health information technology initiatives. Unique architecture provides flexibility to sustain your vision for future IT infrastructure to support best practices and enable continuous quality improvements.

User-friendly interface – Simple, intuitive programming and confirmations screens enables quick training.  Large color-coded screen displays infusion settings at all times. Visual indicators and alarms are differentiated by color and sound making it easier to identify alarms and interpret therapy trends and patient activity.

Graphical Reports - On-screen graphs and trend reports provide delivery history for quick assessment to promote immediate patient care management.

Safety Software - CADD™-Solis Medication Safety Software – Administrator reduces the risk of medication delivery errors, improves patient safety, and increase clinician confidence and productivity. The Administrator software allows pharmacists to enter and store custom therapy-based protocols, drug names, concentrations and dosing limits for standardized programming downloads to CADD®-Solis pumps. The software is designed to safely and effectively program and collect data from the CADD®-Solis Ambulatory Infusion pump.

CADD® Medication Cassette Reservoirs and CADD® Administration Sets contain or connect to medication, fit securely on the pump, keep drugs safe and provide free-flow protection.

Leading Safe, Simple, Smart pump technology to improve your patient comfort while helping you to:

  • Focus on your patient's recovery
  • Provide the best pain management
  • Accurately assess your patient

Common Applications / Procedures Using CADD®-Solis:

  • IV PCA
  • Subcutaneous
  • Epidural
  • Nerve Blocks
  • Surgical Site Infusion

Treatment Areas:

  • Labor and Delivery
  • Peri-Operative care
  • Trauma

Ordering Information

Box quantity: 1
Minimum order quantity: 1


Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.

Product Specifications

CADD®-Solis Ambulatory Infusion Pump

Reorder Code Package includes
21-2111-0400-51
Pump kit, CADD®-Solis, MDL 2110, V4.0, CE English
21-2112-0400-51 Pump kit, CADD®-Solis, MDL 2110, V4.0, Yellow, CE English
21-2130
CADD®-Solis Wireless Communication Module

Accessories

Reorder Code Description
21-2128 Operator's Manual and Administration Settings Guide CD
21-2135 Polemount Adapter (For use with lockable polemount bracket, item #21-6120)
21-2140 AC Adapter (For use with power cord, item #21-2145)
21-2145 U.S. Power Cord (For use with AC Adapter, item #21-2140)
21-2160 Battery Pack, Rechargeable, Standard-life
21-2183 Polemount Adapter Swivel Assembly
21-2184 Battery Door
21-2185 Pump Key (For use with all CADD® pumps)
21-2186 Remote Dose Cord
21-2191 Technical Manual CD
21-6120 Lockable Polemount Bracket

CADD™-Solis Medication Safety Software

Reorder Code Description
21-2194-0402-25 CD, CADD-Solis, MSS, Pharmguard Administrator, 4.2
21-2197 Windows®-based application used by clinicians to access, select and download approved up-to-date pain management protocols per the physician order to safely and accurately program the pump. License to install and use the software. (CD ROM #21-2193) Compatible with CADD®-Solis and CADD-Prizm® PCS II pumps (software revision H or higher).
21-2198 Maintenance Program
21-2199 Administrator License
Notes: The CADD®-Solis pump requires a USB type A to Mini B for connection. The CADD-Prizm® PCS II pump requires an interface cable/null modem cable set.