Minipacks for US and Canada
open| Reorder Code | Tuohy Needle | Nylon Catheter | Plastic LOR | Catheter Label | LockIt Plus |
| 4950-16* | 16G x 3" | Close Ended Multiport | - | Yes | - |
| 4950-17* | 17G x 3 1/2" | Close Ended Multiport | - | Yes | - |
| 4951-17 | 17G x 3 1/2" | DuraFlex® Close Ended Multiport | 7mL Luer Slip | Yes | - |
| 4954-16 | 16G x 3" | Close Ended Multiport | 4mL Luer Slip | Yes | - |
| 4954-17 | 17G x 3 1/2" | Close Ended Multiport | 4mL Luer Slip | Yes | - |
Notes: Only Available in USA & Canada. All standard configurations include the following components unless otherwise noted: Catheter Support Pad, Catheter Connector, 0.2 micron Flat Filter, Threading Assist Guide, Attachable Wings. *Note: No Flat Filter.
System 1 (Not Available in the USA or Canada)
open| Reorder Code | Tuohy Needle | Nylon Catheter | Plastic LOR | Catheter Label | LockIt Plus |
| 100/391/016 | 16G x 80mm | Open Ended | 10mL | Yes | - |
| 100/391/018 | 18G x 80mm | Open Ended | 10mL | Yes | - |
| 100/391/116 | 16G x 80mm | Close Ended Multiport | 10mL | Yes | - |
| 100/391/118 | 18G x 80mm | Close Ended Multiport | 10mL | Yes | - |
| 100/391/126 | 16G x 80mm | Close Ended Multiport | 10mL | Yes | Yes |
| 100/391/128 | 18G x 80mm | Close Ended Multiport | 10mL | Yes | Yes |
| 100/391/190 | 19G x 80mm | Open Ended | 10mL | Yes | - |
| 100/391/318 | 18G x 80mm* | Close Ended Multiport | 10mL | Yes | - |
| 100/391/516 | 16G x 110mm | Close Ended Multiport | 10mL | Yes | - |
| 100/391/518 | 18G x 110mm | Close Ended Multiport | 10mL | Yes | - |
| 100/391/816 | 16G x 80mm | Closed Ended 3 Closer Eyes | 10mL | Yes | - |
| 100/391/818 | 18G x 80mm | Closed Ended 3 Closer Eyes | 10mL | Yes | - |
| G747** | 17G x 80mm | Open Ended | 7mL | - | - |
| G748** | 18G x 80mm | Close Ended Multiport | 7mL | - | - |
| G749** | 18G x 80mm | Open Ended | 7mL | - | - |
| G998** | 17G x 80mm | Close Ended Multiport | 7mL | - | - |
Notes: All standard configurations include the following components unless otherwise noted: Catheter Connector, Threading Assist Guide, 0.2 micron Flat Filter, Attachable Wings. *High Stiffness. **Box quanity: 20.
System 2 (Not Available in the USA or Canada)
open| Reorder Code | Tuohy Needle | Nylon Catheter | Plastic LOR | Catheter Label | LockIt Plus |
| 100/392/116 | 16G x 80mm | Close Ended Multiport | - | Yes | - |
| 100/392/118 | 18G x 80mm | Close Ended Multiport | - | Yes | - |
| E623** | 17G x 80mm | Open Ended | - | - | - |
| G746** | 18G x 80mm | Close Ended Multiport | - | - | - |
Notes: All standard configurations include the following components unless otherwise noted: Catheter Connector, Threading Assist Guide, 0.2 micron Flat Filter, Attachable Wings. **Box quanity: 20.
System 3 (Not Available in the USA or Canada)
open| Reorder Code | Nylon Catheter | Catheter Label | Description | Tuohy Needle | Plastic LOR | LockIt Plus |
| 100/393/116 | Close Ended Multiport | Yes | For use with 16G Needles | - | - | - |
| 100/393/118 | Close Ended Multiport | Yes | For use with 18G Needles | - | - | - |
Notes: All standard configurations include the following components unless otherwise noted: Catheter Connector, Threading Assist Guide, 0.2 micron Flat Filter. Does not contain a Tuohy Needle or Attachable Wings.
System 4 (Not Available in the USA or Canada)
open| Reorder Code | Tuohy Needle | Nylon Catheter | Catheter Label | Plastic LOR | LockIt Plus |
| 100/394/116 | 16G x 80mm | Close Ended Multiport | Yes | - | - |
| 100/394/118 | 18G x 80mm | Close Ended Multiport | Yes | - | - |
Notes: All standard configurations include the following components unless otherwise noted: Catheter Connector, Threading Assist Guide, Attachable Wings. Does not contain a 0.2 micron Flat Filter.